| Order-No. | Description | |
|---|
| 043-102303 | Cleanalyzer Advanced | |  |
| | - Analysing System for Residue Dirt Analysis
- - Automatic measurment of particle-size and shape
- with minimum Particle-Size of 50µm.
- - For Analysing regarding to VDA Bd.19, ISO 16232,
- ISO4406, and own standards.
- - Direct reporting in Excel
- - Direct Export to dhs-Database
- - Easy creation of own standards
- - Analysing of Component Cleanliness Code
- - Statstical Features of results
- - powerful classification options
- - for all filters and filtersizes
- Consisting of:
- - Optics with fixed magnification
- - LED Illumination optimized for best contrast
- - USB Camera 1/2'' 1.3MPx
- - manual measuring stage
- - manual coarse-fine Z-axis
- - solid stand
- - light-control
- - Cleanalyzer Software
- Optics with the following parameters:
- - Field of View X: 6mm
- - Pixelsize min.: 4,7µm
- - min. particle-size according VDA Bd. 19: 50µm
- Software with the following parameters
- - Camera control: image-grabbing, timing,
- gain-control, colour-control, profiles
- - Classifiers: automatic filterprocess to find
- particles with certain features
- - particle typing: manual or automatic process
- to define certain particles as different types
- (e.g. metal, fibres...)
- - result-management: shows result as table and
- chart with different contents (all, different
- types, max. number ...)
- - statistics: allows to show the results with
- different contents (all, per 100cm, per part,
- fraction of types ...)
- - easy creation of own standards
- - Component Cleanliness Code: easy use
- of CCC - including statistic values
- - over 50 parameters to be calculated for each
- particle (shape, size, grey-level, reflecting
- parameter ...)
- - automatic threshhold level
- - offline mode and series
- - profiles for different tasks/parts
- - fully customizable
- - remote controlable
|
| Order-No. | Description | |
|---|
| 043-102307 | Cleanalyzer Professional 50 µm | |  |
| | - Analysing System for Residue Dirt Analysis
- - Automatic measurment of particle-size and shape
- with minimum Particle-Size of 15µm.
- - For Analysing regarding to VDA Bd.19, ISO 16232,
- ISO4406, and own standards.
- - Direct reporting in Excel
- - Direct Export to dhs-Database
- - Easy creation of own standards
- - Analysing of Component Cleanliness Code
- - Statstical Features of results
- - powerful classification options
- - for all filters and filtersizes
- Consisting of:
- - High resolution optics
- - LED Illumination optimized for best contrast
- - USB Camera 1/2'' 1.3MPx
- - motorized precision X-Y Stage
- - manual coarse-fine Z-axis
- - solid stand
- - light-control
- - Cleanalyzer Software
- Optics with the following parameters:
- - Field of View: 5,04mm x 3,76mm
- - Pixelsize min.: 3,9 µm
- - min. particle-size according VDA Bd. 19: 39µm
- Software with the following parameters
- - Camera control: image-grabbing, timing,
- gain-control, colour-control, profiles
- - Classifiers: automatic filterprocess to find
- particles with certain features
- - particle typing: manual or automatic process
- to define certain particles as different types
- (e.g. metal, fibres...)
- - result-management: shows result as table and
- chart with different contents (all, different
- types, max. number ...)
- - statistics: allows to show the results with
- different contents (all, per 100cm, per part,
- fraction of types ...)
- - easy creation of own standards
- - Component Cleanliness Code: easy use
- of CCC - including statistic values
- - over 50 parameters to be calculated for each
- particle (shape, size, grey-level, reflecting
- parameter ...)
- - automatic threshhold level
- - offline mode and series
- - profiles for different tasks/parts
- - fully customizable
- - remote controlable
|
| 043-102302 | Cleanalyzer Professional 15 µm | |  |
| | - Analysing System for Residue Dirt Analysis
- - Automatic measurment of particle-size and shape
- with minimum Particle-Size of 15µm.
- - For Analysing regarding to VDA Bd.19, ISO 16232,
- ISO4406, and own standards.
- - Direct reporting in Excel
- - Direct Export to dhs-Database
- - Easy creation of own standards
- - Analysing of Component Cleanliness Code
- - Statstical Features of results
- - powerful classification options
- - for all filters and filtersizes
- Consisting of:
- - Optics with dented 7:1 Zoom
- - LED Illumination optimized for best contrast
- - USB Camera 1/2'' 1.3MPx
- - motorized precision X-Y Stage
- - manual coarse-fine Z-axis
- - solid stand
- - light-control
- - Cleanalyzer Software
- Optics with the following parameters:
- - Field of View: 1,5 x 1,1 - 8,8 x 6,5
- - Pixelsize min.: 1,17µm
- - min. particle-size according VDA Bd. 19: 15µm
- Software with the following parameters
- - Camera control: image-grabbing, timing,
- gain-control, colour-control, profiles
- - Classifiers: automatic filterprocess to find
- particles with certain features
- - particle typing: manual or automatic process
- to define certain particles as different types
- (e.g. metal, fibres...)
- - result-management: shows result as table and
- chart with different contents (all, different
- types, max. number ...)
- - statistics: allows to show the results with
- different contents (all, per 100cm, per part,
- fraction of types ...)
- - easy creation of own standards
- - Component Cleanliness Code: easy use
- of CCC - including statistic values
- - over 50 parameters to be calculated for each
- particle (shape, size, grey-level, reflecting
- parameter ...)
- - automatic threshhold level
- - offline mode and series
- - profiles for different tasks/parts
- - fully customizable
- - remote controlable
|
| 043-102305 | Cleanalyzer Professional 5 µm | |  |
| | - Analysing System for Residue Dirt Analysis
- - Automatic measurment of particle-size and shape
- with minimum Particle-Size of 5µm.
- - For Analysing regarding to VDA Bd.19, ISO 16232,
- ISO4406, and own standards.
- - Direct reporting in Excel
- - Direct Export to dhs-Database
- - Easy creation of own standards
- - Analysing of Component Cleanliness Code
- - Statstical Features of results
- - powerful classification options
- - for all filters and filtersizes
- Consisting of:
- - Optics with dented 7:1 Zoom
- - LED Illumination optimized for best contrast
- - USB Camera 1/2'' 1.3MPx
- - motorized precision X-Y Stage
- - motorized Z-axis
- - solid stand
- - light-control
- - Cleanalyzer Software
- Optics with the following parameters:
- - Field of View: 0,6mmx0,5mm - 4,3mmx3,5mm
- - Pixelsize min.: 0,5µm
- - min. particle-size according VDA Bd. 19: 5µm
- Software with the following parameters
- - Camera control: image-grabbing, timing,
- gain-control, colour-control, profiles
- - Classifiers: automatic filterprocess to find
- particles with certain features
- - particle typing: manual or automatic process
- to define certain particles as different types
- (e.g. metal, fibres...)
- - result-management: shows result as table and
- chart with different contents (all, different
- types, max. number ...)
- - statistics: allows to show the results with
- different contents (all, per 100cm, per part,
- fraction of types ...)
- - easy creation of own standards
- - Component Cleanliness Code: easy use
- of CCC - including statistic values
- - over 50 parameters to be calculated for each
- particle (shape, size, grey-level, reflecting
- parameter ...)
- - automatic threshhold level
- - offline mode and series
- - profiles for different tasks/parts
- - fully customizable
- - remote controlable
- - interface to dhs image-database
- - automatic report tool
- (fully configurable)
|
Cleanalyzer Stereo
- Unique design, combining the advantages of stereo- and TVmicroscopy:
- For measurements video microscopes offer high resolution anda completely perpendicular optical path
- A Stereo Microscope provides the best impressions for visual inspection of particles, having different images projected to the left and right eye, resulting in a very real, natural 3D impression
- User can choose between 3 different positions:
• High-resolution measurement with a micro objective (like a common TV-Microscope)
• Low-resolution measurement with stereo objective (use of stereo objective moved into the optical path of the TV-Microscope)
• Binocular visual inspection with stereo objective (3D visual inspection like a pure Stereo-Microscope: 3D Impression of particles)
- Fully automated process runs
- PC controlled x/y stage with additional manual joystick
- Optimised LED ringlight illumination
- Measuring particles down to 5 µm
| Order-No. | Description | |
|---|
| 043-102304 | Cleanalyzer Stereo | |  |
| | - Analysing System for Residue Dirt Analysis
- - Automatic measurment of particle-size and shape
- with minimum Particle-Size of 5µm.
- - For Analysing regarding to VDA Bd.19, ISO 16232,
- ISO4406, and own standards.
- - Direct reporting in Excel
- - Direct Export to dhs-Database
- - Easy creation of own standards
- - Analysing of Component Cleanliness Code
- - Statstical Features of results
- - powerful classification options
- - for all filters and filtersizes
- Consisting of:
- - Optics with 2 Objektives
- Stereo objektive and high-resolution micro-
- objective magnification changer with 5
- different magnifications for each objective
- - objective slider to move objectives in 3
- positions: Stereo View, Stereo measure,
- high-resolution measure
- - automatic magnification control by software
- - 2 LED Illumination optimized for best contrast
- - USB Camera 1/2'' 1.3MPx
- - motorized precision X-Y Stage
- - motorized Z-axis
- - solid stand
- - light-control
- - Cleanalyzer Software
- Optics with the following parameters:
- - Field of View Micro:0,6mmx0,5mm - 1,7mmx1,36mm
- - Field of View Stereo: 1,3mmx1mm - 8,5mmx6,8mm
- - Pixelsize min.: 0,51µm
- - min. particle-size according VDA Bd. 19: 5µm
- Software with the following parameters
- - Camera control: image-grabbing, timing,
- gain-control, colour-control, profiles
- - Classifiers: automatic filterprocess to find
- particles with certain features
- - particle typing: manual or automatic process
- to define certain particles as different types
- (e.g. metal, fibres...)
- - result-management: shows result as table and
- chart with different contents (all, different
- types, max. number ...)
- - statistics: allows to show the results with
- different contents (all, per 100cm, per part,
- fraction of types ...)
- - easy creation of own standards
- - Component Cleanliness Code: easy use
- of CCC - including statistic values
- - over 50 parameters to be calculated for each
- particle (shape, size, grey-level, reflecting
- parameter ...)
- - automatic threshhold level
- - offline mode and series
- - profiles for different tasks/parts
- - fully customizable
- - remote controlable for worldwide
- service and support
- - interface to dhs image database
- - automatic report tool for MS-Excel
- (fully customizable)
|